Video reference. Adam Stears of SOTA Electrical, an OZEV-approved EV charger installer in Hampshire, gives a first-time review of the NexBlue Point 2 in "I've Never Heard of This EV Charger… But It's Brilliant." He covers unboxing, the backplate installation method, app commissioning and his verdict on the charger's real-world suitability for UK domestic installs.
1. Assessing the consumer unit and incoming supply
Before anything else, your electrician will confirm the consumer unit has a spare way for a new 32A RCBO. They will also measure the actual current draw on the incoming supply during peak use, typically early evening, using a clamp meter. A 7.4 kW NexBlue Point 2 draws around 32A, so the existing service needs enough headroom.
Most modern 100A single-phase supplies handle a 7.4 kW charger comfortably. Older properties with a 60A or 80A cut-out fuse, or those already running several high-demand appliances simultaneously, need a more careful load calculation. If the consumer unit has no spare ways or is an old rewireable fuse box, the electrician may recommend upgrading the board at the same time.
2. Choosing the mounting position
The most common position is the outside wall of the house beside the driveway, or the inside or outside of a garage. The Point 2 is rated IP54, so it can go outside year-round, though a sheltered spot under an eave keeps the Type 2 socket and weather cap in better condition long-term.
Height of around 0.8 m to 1.2 m from the ground is standard. The position also depends on where the cable can run from the consumer unit without crossing structural elements or exceeding the cable's voltage drop limit. For a garage installation, your electrician will check whether the cable route goes through the loft void, externally along the wall, or underground across the driveway.
3. Running the supply cable
A 7.4 kW NexBlue Point 2 runs on 6 mm two-core and earth cable on a 32A circuit. For a wall-to-wall installation close to the consumer unit the cable run is short. For a detached garage or a driveway on the far side of the house, the route often involves surface conduit on external walls and a buried SWA (steel wire armoured) cable run underground.
Underground cable must be at least 450 mm deep and mechanically protected where it crosses a driveway or any area vehicles use. A short, straight cable run from the consumer unit keeps costs down. If the route is complicated, it is worth discussing this during the quote to avoid surprises.
4. Fitting the RCBO in the consumer unit
The new circuit gets a dedicated 32A Type B RCBO in the consumer unit. The NexBlue Point 2 has built-in Type A DC leakage protection as part of its internal electronics, so an upstream RCBO providing overcurrent protection and a local means of isolation is sufficient. Your electrician will connect the 6 mm live to the RCBO, the neutral to the neutral bar or RCBO neutral terminal, and the earth to the earth bar, then label the circuit clearly.
Some older consumer units have main switches that cannot safely accept a 32A addition without first checking the cumulative load on the busbar. This is part of the initial consumer unit assessment and not something to worry about separately.
5. Mounting the backplate and wiring the unit
One of the Point 2's practical advantages is its separate backplate. The backplate screws to the wall first, and all the cable work can be completed and tested before the unit itself is clipped on. This matters when the mounting surface is awkward or when access is limited.
Your electrician will thread the supply cable through the gland on the backplate, strip it to the right lengths, and connect Line, Neutral and Earth to the correct terminals. The unit then clips firmly onto the backplate. The gland is tightened to maintain the IP54 rating.
6. Commissioning via the MyNexBlue app
Once power is restored, the Point 2 connects to the mobile network automatically via its built-in 4G eSIM. No Wi-Fi password or router configuration is needed, which simplifies commissioning in outbuildings or on driveways beyond the range of a typical home router.
Your installer or you can then configure the unit through the MyNexBlue app:
- Charging schedule. Set the unit to charge automatically during your off-peak tariff window (Octopus Go, British Gas Electric Driver, etc.) or whenever you plug in.
- Solar charging. If you have solar panels, the Point 2 can be set to charge only on surplus generation, with a minimum rate of around 1.4 kW (6A). The specific setup depends on how your solar system exports data, so discuss this with your installer.
- Test charge. Plug your car in and confirm the display shows the expected charge session, the app shows the correct power level, and the unit stops correctly when commanded.
When to call us
Richard covers EV charger installations across east Kent, including Sandwich, Deal, Ramsgate, Folkestone and the surrounding villages. Quotes include all materials, the RCBO and the Electrical Installation Certificate. If you are unsure whether your existing supply and consumer unit can handle a 7.4 kW charger, Richard can carry out a supply assessment visit first.