5% off for pensioners

How-to · UK domestic

How to wire a Viessmann Vitocal electrical supply (UK)

The Vitocal 150-A and 151-A are monobloc R290 heat pumps: all the refrigerant components live in the outdoor unit, and only the water circuit crosses the building threshold. That keeps the electrical side straightforward -- one dedicated circuit from consumer unit to outdoor terminal block -- but the R290 (propane) refrigerant means you need to pay attention to cable entry points and clearances in a way you would not with older refrigerants. Download the installation manual for your specific model output before you start: Viessmann publishes rated currents, cable cross-sections and torque settings per model in the electrical data table, and those figures are the ones that govern the job.

Helpful video reference. This guide uses the official product overview for the Vitocal 150-A and 151-A published by Viessmann UK (headquartered in Telford) on their official YouTube channel as a companion to the written installation manual. For the full wiring detail, work from the installation and service instructions for contractors for your specific model, available from the Viessmann installer portal.

Before you start. Wiring the electrical supply to a Viessmann Vitocal 150-A or 151-A heat pump is notifiable work under Part P of the Building Regulations. This work must be carried out by a qualified, Part P-registered electrician. This guide is written for qualified electricians doing the electrical first fix and not for homeowners attempting DIY electrical work. Always isolate the consumer unit before working in it and confirm dead with a calibrated voltage tester before touching any terminal. The Vitocal uses R290 (propane) as its refrigerant: if you smell gas at any point, stop work immediately and contact the heat pump engineer before continuing.

1. Identify the Vitocal model and check the installation manual

The model number is on the outdoor unit nameplate, usually inside the service panel or on the front casing label. The 150-A is the wall-mounted variant and the 151-A is the floor-standing variant; both share the same R290 refrigerant circuit, but the electrical compartment access and cable entry routes differ between the two housings.

Viessmann launched the original 10, 13 and 16 kW outputs in April 2022 and added 4, 5, 6 and 8 kW variants in July 2023. The rated current and maximum overcurrent protective device rating differ between output sizes, so download the installation and service instructions for contractors for your specific model from the Viessmann installer portal before quoting or ordering materials. Work from the electrical data table: that is the authoritative source for RCBO rating, cable cross-section and terminal torque values.

If the installation includes a Viessmann OneBase wiring centre for controls integration, check whether it draws its supply from the heat pump's internal transformer or requires a separate 5A fused spur circuit from the consumer unit. The installation manual for the OneBase will confirm this.

2. Fit a dedicated Type A RCBO in the consumer unit

Fit a Type A RCBO, not Type AC, in a spare way at the consumer unit. Confirm the RCBO current rating from the electrical data table in the Viessmann installation manual for your exact model and output. Smaller 4-6 kW models typically require a 16-20A device; larger 10-16 kW models typically require a 25-32A device. Always use the figure from the manual rather than a rule of thumb, and size the RCBO to the rated value without rounding up beyond what the manual permits.

Type AC RCBOs are not acceptable. The Vitocal 150-A uses a variable-speed inverter that can produce a DC leakage component in a fault condition, which a Type AC device will not detect. Viessmann specifies a Type A device as the minimum for all R290 Vitocal models.

Label the RCBO: "Heat Pump -- Viessmann Vitocal [model]". A service engineer coming to the installation months after commissioning needs to identify the circuit without tracing the cable.

3. Run the supply cable to the outdoor unit

The Vitocal 150-A and 151-A are monobloc units: the refrigerant circuit, compressor and electric backup heater are all contained in the outdoor unit. Only the water and glycol circuits connect the outdoor unit to the building's internal hydraulics. A single supply cable from the RCBO in the consumer unit to the outdoor unit terminal block is all that is required for the main heat pump circuit.

Cable cross-section depends on the rated current in the installation manual and the actual run length from the consumer unit to the outdoor unit. Run the BS 7671 voltage drop calculation for the full route: voltage drop must remain within 3% at the rated current. For typical domestic runs at the smaller output ratings, 4 mm² twin-and-earth covers most cases up to around 20-25 metres; check the calculation for your specific model and actual run length before ordering cable.

All exposed cable must run in conduit or surface trunking. Any cable chased into plaster must follow a recognised safe zone as defined in BS 7671 or run in metallic conduit. Where the cable route crosses a fire compartment wall or ceiling, use approved fire-rated sleeves and seal both sides.

4. Fit the TPN outdoor isolator within sight of the outdoor unit

Mount a weatherproof TPN isolator (IP65 minimum; IP66 is preferable on exposed elevations) on the external wall within direct sight of the outdoor unit. The isolator must disconnect all poles including neutral and must be lockable in the off position.

The siting requirement is functional: a service engineer crouching at the outdoor unit must be able to see the isolator handle and confirm it is in the off position without leaving the work area. In practice, within 2-3 metres on the same wall face satisfies this in almost all domestic installations. If the outdoor unit is sited away from the building wall, check that sight lines are clear before finalising the isolator position.

The supply cable from the indoor consumer unit terminates at the isolator's supply terminals. From the load terminals, run a short section of SWA or twin-and-earth in weatherproof conduit to the outdoor unit's electrical compartment. Keep this external section as short as practical.

5. Observe R290 safety requirements at the outdoor unit

R290 is propane: flammable above its lower flammability limit and denser than air, so it settles in low areas such as drains and gullies. Viessmann specifies minimum clearances from drainage openings, ignition sources and ventilation inlets in the installation manual, and the heat pump engineer will have sited the outdoor unit to meet those clearances. Your job is to ensure that the electrical work does not compromise them.

All cable entry points into the outdoor unit electrical compartment must use the cable glands or entry details shown in the Viessmann installation manual. Do not create additional openings in the outdoor unit casing or housing, and do not use sealants other than those specified: the enclosure integrity matters for both weather exclusion and refrigerant containment.

If you detect a smell of gas while working at the outdoor unit, treat it as a refrigerant leak: stop work, ventilate the area and contact the heat pump engineer before continuing. R290 ignites from sparks, so do not use power tools or create arcing in the area until the engineer has confirmed the unit is safe.

6. Wire the outdoor unit terminal block following Viessmann's wiring diagram

Open the outdoor unit electrical compartment using the fasteners shown in the installation manual. The main terminal block carries the terminal identifiers shown in the wiring diagram for your model: typically L (phase), N (neutral) and an earth terminal, with a separate chassis earth terminal on the unit frame. Connect the conductors to the correct terminals using the wiring diagram as your reference, not a generic diagram for a different model.

Tighten all connections to the torque settings listed in the Viessmann installation manual using a calibrated torque screwdriver. Viessmann specifies torque values for each terminal size; under-tightened connections cause voltage drop and overheating, and over-tightened ones crack terminal housings. Connect the earth conductor to the chassis earth terminal as well as the terminal block earth point: both are required and both are shown in the wiring diagram.

Once connections are made, check that all cable glands are tight, that no cable sheath is damaged inside the compartment, and that the compartment cover can be refitted fully before closing up.

7. Submit G98 notification to the DNO and issue the EIC

Once the heat pump engineer has commissioned the system, submit the G98 self-notification form to the relevant distribution network operator within 28 days of commissioning. G98 self-notification applies to most standard domestic single-phase heat pump installations. For three-phase supplies or where the Vitocal forms part of a larger renewable energy installation, check whether G99 applies instead, as G99 requires DNO approval before commissioning.

Issue an Electrical Installation Certificate covering the new supply circuit. Hand it to the homeowner alongside the heat pump engineer's commissioning documentation, MCS certificate and Viessmann warranty registration confirmation. The homeowner will need all of these documents if they are applying for the Boiler Upgrade Scheme grant.

Stop and call a specialist if: the consumer unit has no spare way for a dedicated RCBO; the main switch rating is marginal for the total connected load; the cable route would require crossing a party wall or roof void without fire-rated protection; any wiring on the cable route has cloth or rubber sheathing; the outdoor unit has been sited closer to drainage openings or ventilation inlets than Viessmann's minimum clearances allow; or you smell gas at the outdoor unit at any point.

When to call us

If you are based in east Kent and have a Viessmann Vitocal being installed, Richard can handle the electrical supply side: RCBO, cable run, TPN outdoor isolator, G98 notification and Part P certificate. Happy to co-ordinate with your Viessmann MCS installer.

Viessmann Vitocal installation in Sandwich or east Kent?

Richard handles the electrical supply: RCBO, cable run, TPN outdoor isolator, G98 notification and Part P certificate. Happy to co-ordinate with your Viessmann MCS installer.

Contact Richard

Related pages