How to wire Grant Aerona controls (UK)

The Grant Aerona³ ASHP uses a wiring centre (the EP001) to manage its zone valves, room thermostats and cylinder thermostat, and an Aerona Smart Controller (GSC) that communicates with the heat pump and handles weather compensation. This article covers the low-voltage and mains controls wiring that sits alongside the main supply circuit, which is dealt with in a separate article on wiring the Grant Aerona electrical supply. The EP001 itself needs a small dedicated 5A supply because it feeds the zone valve motors; treat that supply as notifiable Part P work.

Helpful video reference. We use Grant UK's official customer handover video as the companion here. The "Controlling the system - Aerona³ Heat Pump Customer Handover" from Grant UK's official YouTube channel (youtube.com/MyGrantUK) gives a clear overview of how the finished control system behaves, which is useful context before the wiring work begins.

Before you start. The Grant Aerona³ controls wiring involves a mix of 230V zone valve connections, the EP001's own mains supply and low-voltage signal connections to the Smart Controller. The 230V work is notifiable under Part P. This guide is written for qualified electricians working alongside a Grant-approved heat pump installer; do not attempt this work without both qualifications and without the system schematic for your specific installation pack.

1. Identify the system type and locate the correct Grant wiring diagram

Grant publishes system schematics for each installation pack (Pack A, C, K, R and others) in the Aerona³ installation manual and on their website. The installation pack is specified in the system design and determines the zone valve arrangement, flow arrangement and EP001 wiring diagram to use.

Download the schematic for your specific installation pack before touching any terminals. The terminal labels on the EP001 correspond directly to labels on the schematic: working from the wrong diagram, or guessing terminal assignments, causes wiring errors that are time-consuming to find during commissioning.

If the system schematic has not been issued, contact the heat pump installer or Grant's technical support before proceeding. Do not attempt to infer the wiring from the EP001 terminals alone.

2. Fit the EP001 wiring centre and its 5A supply

Mount the EP001 near the cylinder and heat pump pipework, in a dry, accessible location. The EP001 is typically surface-mounted on the wall adjacent to the cylinder.

The EP001 requires a dedicated 5A fused supply. This can be taken from an existing circuit as a 5A switched fused connection unit (FCU), or from a new 6A MCB at the consumer unit. This supply is Part P notifiable because it is a new circuit or new fixed connection: include it on the Electrical Installation Certificate.

Do not share the EP001 supply with other loads. The EP001 feeds power to the zone valve motors and must have a clean, dedicated feed to avoid interaction with other connected equipment.

3. Connect the two-port zone valves to the EP001

Connect each zone valve motor wire to the valve output terminals on the EP001, following the labels on the schematic for your installation pack. Typical terminals are labelled Zone 1, Zone 2 and DHW, but confirm against the specific schematic.

Connect the zone valve end microswitch to the pump call terminal on the EP001. This ensures the circulation pump only runs when at least one zone valve is open, which is correct system behaviour for a Grant Aerona installation.

Zone valve wiring is 230V: treat the EP001 output terminals and all zone valve connections as mains electrical work. Isolate the EP001 supply before making connections at the EP001 terminals or at the valve bodies.

4. Connect the room thermostat or Smart Controller room module

For a Grant wired thermostat (GTTH or compatible), connect to the thermostat input terminals on the EP001 or directly to the GSC room thermostat input as specified in the schematic for your installation pack.

For the Grant wireless thermostat (GTSWTS or GTSWTS2), no wiring is needed at the thermostat itself: the wireless thermostat pairs to the Smart Controller via a menu option on the GSC once the GSC is powered and commissioned.

Third-party room thermostats must use a volt-free contact. Connect the thermostat's volt-free output contacts to the thermostat input terminals on the EP001. Do not connect a live-voltage thermostat output to any EP001 control terminal: live contacts will damage the board.

5. Connect the DHW cylinder thermostat

Connect the cylinder thermostat to the DHW thermostat input on the EP001. Use a standard 240V cylinder thermostat with two-position contacts. The EP001 reads the top position contact (the lower-temperature position on a dual-element thermostat) as the DHW call signal.

Set the cylinder thermostat to the design temperature specified by the system designer, typically 60°C to meet legionella risk management guidance. If the system design specifies a different setting, follow the design rather than a default.

Some installation packs use a second cut-out thermostat in addition to the primary thermostat. If your schematic shows two cylinder thermostat connections, fit both and confirm which terminal each connects to.

6. Connect the Grant Aerona Smart Controller signal cable

Run the GSC signal cable from the outdoor unit terminal block to the GSC control board inside the building. This is a low-voltage, non-mains signal cable: it must not be run in the same conduit or trunking as mains cables.

Keep the signal cable at least 100 mm from mains wiring throughout its route, and use screened cable if the run is long or passes parallel to mains wiring for more than a few metres. Connect to the terminal identifiers shown in the GSC wiring diagram.

The signal cable carries both the communication signal between the heat pump and the GSC and, depending on the installation pack, may also carry a low-voltage sensor signal. Follow the GSC installation guide precisely for the terminal connections at both ends.

7. Commission the controls and test all zones

Restore power to the EP001 and the GSC. Trigger a heating call for zone 1: the zone 1 valve should open, the pump call terminal should close and the heat pump should start. If the heat pump does not start, confirm the GSC is communicating with the outdoor unit and check the signal cable connections at both ends.

If a second heating zone is fitted, test it independently by triggering a zone 2 call with zone 1 inactive. Confirm the zone 2 valve opens and the heat pump responds correctly.

Trigger a DHW call and confirm the DHW zone valve opens and the heat pump switches to DHW priority mode. Configure weather compensation in the GSC settings following Grant's commissioning guide. Issue the Electrical Installation Certificate for the EP001 supply circuit.

Stop and call the heat pump installer if: the system schematic has not been issued for this installation pack; there are zone valve connections that do not match any terminal label on the EP001; the Smart Controller does not power up after the GSC signal cable is connected; or the DHW zone valve opens but the heat pump does not switch to DHW priority mode.